Display Diagnostics - ACP AXP20 Service Manual

High speed combination oven
Hide thumbs Also See for AXP20:
Table of Contents

Advertisement

Error Codes
Display Description
b0
Touch Panel
b1
Touch Panel
c-0
Temp sensor (rTD) (open)
c-1
Temp sensor (rTD) (shorted)
c-2
Temp sensor (rTD) (out of range)
D-0
Thermocouple (rTD) (open)
D-1
Thermocouple (rTD) (shorted)
D-2
Thermocouple (rTD) (out of range) replace Thermocouple
G-0
Oven exceeded max. Temp.
G-2
magnetron TcO
G-2
cooling motor
H-0
signal missing
H-1
main board set Point incorrect.
H-2
main board
H-3
main board
m-0
current sense Low amps
m-1
magnetron 1 Low amps
m-2
magnetron 2 Low amps
Note: While in the service test the error history can be cleared by pressing and holding Pad 1
see page 28.
*if G-0 continues to appear. replace electronic Limiter.

Display Diagnostics

Corrective Action
replace Touch Panel
replace Touch Panel
replace Temp sensor
replace Temp sensor
replace Temp sensor
replace Thermocouple
replace Thermocouple
unplug / Plug oven in*
Perform service test (magnetron #1 & #2)
Perform service test (cooling Fan)
Plug disconnected from J1 on main board
unplug / Plug oven in
replace main board
replace main board
Perform service test (magnetron #1 & #2)
Perform service test (magnetron #1)
Perform service test (magnetron #2)
20