Model Name (Combination Unit)
Model Name (Independent Unit)
1 Cooling Capacity
2 Heating Capacity
Casing Color
Dimensions: (H×W×D)
Heat Exchanger
Type
Piston Displacement
Number of Revolutions
Comp.
Motor Output×Number
of Units
Starting Method
Type
Motor Output
Fan
Airflow Rate
Drive
Liquid Pipe
Connecting
Pipes
Gas Pipe
Mass (Weight)
Safety Devices
Defrost Method
Capacity Control
Refrigerant Name
Refrigerant
Charge
Control
Refrigerator Oil
Standard Accessories
Drawing No.
Notes:
1 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
2 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5m, level difference
Specifications
kcal / h
Btu / h
kW
kcal / h
Btu / h
kW
mm
m³/h
r.p.m
kW
kW
m³/min
kg
High pressure switch, fan driver overload protector, overcurrent relay, inverter overload protector
%
kg
difference : 0m.
: 0m.
RQCYQ540PY1
RQYQ180PY1+RQYQ180PY1+RQYQ180PY1
46,400
184,200
54.0
51,600
204,700
60.0
Ivory White 5Y7.5/1
1680×635×765+1680×635×765+1680×635×765
Cross fin coil
Hermetically sealed scroll type
(15.75×1)+(15.75×1)+(15.75×1)
7440, 7440, 7440
(3.3×1)+(3.3×1)+(3.3×1)
Soft start
Propellor fan
(0.35×1)+(0.35×1)+(0.35×1)
110+110+110
Direct drive
φ
15.9 C1220T (Brazing connection)
φ
28.6 C1220T (Brazing connection)
175+175+175
Deicer
7-100
R-410A
11.1+11.1+11.1
Electronic expansion valve
Refer to the nameplate of compressor
Installation manual, Operation manual, Connection pipes, Cramps
Specifications
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
10