Indication
Function
Counter operation
Selection of pedal
Selection of start pedal
Optional pedal 1 operation
Optional pedal 2 operation
Height of work clamp foot at the
time of 2-step stroke
Selection of base point of pattern
enlargement/reduction
Sewing machine operation can be
stopped with panel key (clear key).
Buzzer sound can be prohibited.
Number of stitches that needle
thread clamp releases is set.
Clamping timing of needle thread
clamp can be delayed.
Needle thread clamp control can
be prohibited.
Feed timing is selected.
When stitches are not well-
tightened, set the value in "–"
direction.
State of work clamp foot after
completion of sewing can be
selected.
Execution of origin retrieval every
time after completion of sewing
can be performed. (Except cycle
stitching)
Setting of origin retrieval in cycle
stitching can be set.
Setting range
0 : Production counter
(adding)
1 : Bobbin thread counter
(subtracting)
0 : Standard pedal
1 : Standard pedal (2-step
stroke)
2 : Optional pedal
3 : Optional pedal (2-step
stroke)
0 : Standard pedal
1 : Optional pedal
0 : OFF when depressing
pedal again
1 : OFF when detaching from
pedal
0 : OFF when depressing
pedal again
1 : OFF when detaching from
pedal
50 to 90
0 : origin
1 : Sewing start point
0 : Ineffective
1 : Panel reset key
2 : External switch
0 : Without buzzer sound
1 : Panel operation sound
2 : Panel operation sound +
error sound
1 to 7 stitches
-10 to 0
0 : Normal
1 : Prohibited
-8 to 16
0 : Work clamp foot goes up
after moving at the sewing
start
1 : Work clamp foot goes up
immediately after the end
of sewing.
2 : Work clamp foot goes up
by pedal operation after
moving at the sewing
start.
0 : Without origin retrieval
1 : With origin retrieval
0 : Without origin retrieval
1 : Every time 1 pattern is
completed
2 : Every time 1 cycle is
completed
43
State when delivered
0
0
0
0
0
70
Height is lowered when the set
value is increased.
0
0
2
2
0
Timing is delayed in "-" direction.
0
Misapplication of panel is
protected. For LK-1903A, set to
"1".
12
Setting on excessive "–" side may
cause needle breakage. Be
careful when sewing heavy-
weight material.
1
For LK-1903A/BR35, set to "0".
0
0