Toshiba TECRA S4 Maintenance Manual page 133

Personal computer
Hide thumbs Also See for TECRA S4:
Table of Contents

Advertisement

3.3 Check of the RAID configuration
NO DRIVE for one drive is displayed
When "NO DORIVE" is displayed and the HDD is connected to the port, follow the
procedures below to check the HDD failure. When the HDD is not connected to the
port, removing of the drive causes the failure. It is not necessary to repair.
(1) Install a new HDD.
When "NO DORIVE" is still displayed, It is judged that the MB or cable fails.
(2) When a new HDD is recognized, It is judged that the HDD removed is failed.
Specify the reason by using the Independent Utility.
TOSHIBA RAID / RAID Information Display
Copyright(c) 2005 TOSHIBA CORPORATION. All Rights Reserved.
Level
LD0 RAID-1
Write cache
MBR Protection
S.M.A.R.T
Port
Assgn Status
0
LD0-0 ONLINE
1
< RAID : not OPTIMAL >
TECRA S3 Maintenance Manual (960-532)
Status
Capacity
DEGRADE
xxGB
: Enable
: Disable
: Enable
Size
xxGB
NODRIVE
xxGB
Rev xx.xx.xxxx
Model
FUJITSU----------
FUJITSU----------
[CONFIDENTIAL]
3 Tests and Diagnostics
Rev
xxxxxxx
xxxxxxx
3-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tecra s3

Table of Contents