DIGI-50 OPERATING INSTRUCTIONS
Temperature Button
To adjust the temperature setting, press and hold down the temperature button
and use the up/down arrow keys to the left of the display to increase or decrease
the set point. (Required Temperature)
Range:- Minimum 70ºC (158ºF), Maximum 240ºC (464ºF).
Note! When selecting operating Modes 1, 3 or 5, the printer will not operate on the
external trigger until the temperature has reached the pre-programmed set point.
(see page 13 for ranges of the mode settings etc.)
In normal operation, the temperature will fluctuate by up to ±4ºc from the set point.
Print Dwell Button
To adjust the print dwell setting, press and hold down the print dwell button and
use the up/down arrow keys to the left of the display to increase or decrease.
This adjustment controls the time the type/die face is in contact with the substrate.
Higher numbers indicate longer dwell times.
Range:- 10 to 4000 milli–seconds. (0.010 – 4.0 Seconds)
Print Switch
Switches the print signal between external trigger (automatic print cycle) and the
test button feature (manual operation).
Switches the audible alarm off when a system fault occurs whilst operating from an
external trigger (automatic print cycle).
Note! The Print LED (green) is illuminated when switched for external triggering
(automatic print cycle).
Test Button.
Manually operates the printer (will not operate whilst the Print LED is on).
Fault LEDs.
Eurocode-Digi50 06/08/13
Refer to pages 22 & 23 for system faults.