Operation - Chloride Power Protection Active 700 Operating Manual

Hide thumbs Also See for Power Protection Active 700:
Table of Contents

Advertisement

4.2.1.2 Operation

The following chart describes functions and operations of these buttons and LEDs
Button/LED
Button 14
Inverter ON/OFF Button
Button 7
Site Wiring Fault E/D Button
Mute Buzzer (Alarm Reset)
Force the unit to bypass or
Button 6
Reset LCM Alarm (alarm which
indicates end of estimated
Show Output Load level
Button 5
Cold Start Enable/Disable
LED 1 (*)
Site Wiring Fault Detection LED
LED 2 (*)
Battery Fault LED
LED 3 (*)
UPS Fault LED
LED 4 (*)
UPS Overload LED
LEDs 1, 2, 3
Battery Capacity Level / Output
& 4 (*)
Site Wiring Fault E/D LED
LED 8
LED 9
Outlet 1 ON/OFF LED
LED 10
Outlet 2 ON/OFF LED
LED 11
Bypass Mode LED
LED 12
Line Mode LED
LED 13
Battery Mode LED
LED 15
Inverter ON LED
(*) These LEDs show battery capacity level or output load level (depending on button 5) and normally they should be read
as a group. However, in case of certain events (SWF, Battery Fault, UPS Fault or UPS Overload), they pass to indicate it by
¿ ashing and should be read individually.
Function
Press one second to switch on/off the inverter
Press seven seconds to enable/disable Site
LED test
Press buttons 6 and 5 for four seconds to force
comeback
the unit to bypass or to return from bypass
Press buttons 6 and 5 for three seconds to
reset this alarm (if the alarm is active, it is
necessary to push these buttons 4 more
battery life)
seconds to switch the unit to bypass, as per
Press to show output load level on LEDs 1, 2
3 and 4 (by default they show battery capacity
Press ¾ ve seconds to enable/disable cold start
Indicates if Site Wiring Fault has been detected
Indicates if a battery fault has been detected
Indicates if a UPS fault has been detected
Indicates if an output overload has been
Indicates battery capacity level (by default), or
Load Level
output load level if button 5 is pressed
Indicates if Site Wiring Fault detection is enabled
or disabled (enabled: ON; disabled: OFF)
Indicates if group 1 of the output controllable
sockets is supplying power or not (supplying
power: ON; not supplying power: OFF; status
Indicates if group 2 of the output controllable
sockets is supplying power or not (supplying
power: ON; not supplying power: OFF; status
Indicates if the unit is on bypass mode (¿ ashing)
Indicates if the unit is on line mode (ON)
Indicates if the unit is on battery mode (ON)
Chloride Active
Operation/De¾ nition
Wiring Fault detection
Press one second to mute the buzzer
Press for LED test (all LEDs ¿ ashing)
above functionality)
level)
functionality
detected
change in progress: ¿ ashing)
change in progress: ¿ ashing)
Indicates if the inverter is ON or OFF