Chloride Desk POWER 300 Operating Manual

230v/120v rs232/usb
Hide thumbs Also See for Desk POWER 300:

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Desk POWER 300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Chloride Desk POWER 300

  • Page 3 CHLORIDE POWER PROTECTION o Uninterruptible Power System Desk POWER Desk POWER Desk POWER Operating Manual...
  • Page 4 All rights, including rights of translation, repro- duction by printing, copying or similar methods, even of parts, are reserved. Offenders will be liable for damages. All rights, including rights created by patent grant of registration of utility model or design, are reserved.
  • Page 5: Table Of Contents

    Operating manual Safety Instructions Explanation of Symbols Introduction Unpacking the Unit & Contents Unpacking the Unit Package Contents Installation The Unit Front Panel 4.1.1 Elements 4.1.2 Funcitonality Rear Panel 4.2.1 230V Version 4.2.1.1 RS232 4.2.1.2 USB 4.2.2 120V Version 4.2.2.1 RS232 4.2.2.2 USB Battery Test Interfaces...
  • Page 6 Operating manual REV: 14/03/01 945014.066...
  • Page 7: Safety Instructions

    Operating manual Safety Instructions CAUTION Please read the following information carefully and save this manual for future reference! Disregard of these safety notes may endanger life or health, as well as the function of the equipment and the safety of your data. ·...
  • Page 8: Explanation Of Symbols

    Operating manual EC /UL/CSA Conformity Declaration · The Chloride Desk Power 230V UPS complies with the regulations of the following European guide- lines: 73/23/EEC Council guideline for EC countries concerning electrical apparatus within certain volta- ge tolerances, modified by the guideline RL 93/68/EEC of the Council. 89/336/EEC Council guideline for EC countries concerning electromagnetic compatibility, modified by the guidelines RL 91/263/EEC, 92/31/EEC and 93/68/EEC of the Council.
  • Page 9: Introduction

    Operating manual 1. Introduction The Chloride DESK POWER series is based on the off-line principle. This means that the equipment connected to the unit is powered by the mains after passing through diverse filters. This way, distur- bances in the power mains are reduced, thereby improving the operational safety of the protected equipment (PC, server systems, extended systems, etc.).
  • Page 10: Unpacking The Unit & Contents

    Operating manual 2. Unpacking the Unit & Contents 2.1 Unpacking the unit. When opening the package, please follow this procedure: 2.- Open the front flap 1.- Place the packaging in a horizontal posi- tion following the arrow indications shown. 3.- Remove the top cover to the back. 4.- Remove the equipment 5.- Remove the protection 6.- Place the equipment in a working position...
  • Page 11: Package Contents

    Operating manual 2.2 Package contents The contents of a DESK POWER package are described below. Please ensure all the items have been correctly received. It any of them have been damaged, please contact your supplier. Once opened, please verify the following items included in the box. These are: - UPS unit: - 2 power cables with IEC 320 or NEMA 5-15...
  • Page 12 Operating manual To correctly install the unit, please follow the procedure described below: 1.Connect the load (i.e. PC CPU, Monitor) to the UPS Battery Protected outlets. Appropriate loads are those units that will require extend run time during blackouts. 2. Connect the selected load (i.e. printer, scanner) to the surge protected outlet. Appropriate loads are those elements that demand surge protection, but that do not require extended runtime during power outages.
  • Page 13 Operating manual 4. Plug the power cable to the AC inlet. 5. Plug the power cable to the mains supply 6. Press the On / Off button on the front panel to start up the UPS. 7. If you have a Shutdown Software license, install the bundled software. To do this, please follow the procedure enclosed with the software license.
  • Page 14: The Unit

    Operating manual 4. Unit elements. 4.1 Front Panel 4.1.1 Elements Described below are the relevant elements located in the front panel. Battery/Line Mode Fault / Overload Alarm Silence On / Off Battery/Line Mode Fault / Overload Alarm Silence On / Off Battery/Line Mode Fault / Overload Alarm Silence...
  • Page 15: Funcitonality

    Operating manual 4.1.2. Functionality The combination of the LED’s and the acoustic signal determines the operation status of the unit. These conditions are summarised in the following table: 4.2. Rear Panel Depicted below, are all the elements located on the rear panel. Depending on the power, the voltage and the type of communications port, the sets are as follows: 4.2.1.
  • Page 16: Usb

    Operating manual 4.2.1.2. USB Outlets Protector Outlets 10A 250V AC AC Inlet Surge Protected Batt. Protected 300 - 500VA Comm Port Fax/Modem Protection Outlets Outlets Surge Protected AC Inlet Batt. Protected 650VA Protector Comm Port Fax/Modem Protection 10A 250V AC 4.2.2.
  • Page 17: Usb

    Operating manual 4.2.2.2. USB Outlets Outlets AC Inlet Surge Protected Batt. Protected 300 - 500VA Protector Comm Port Fax/Modem Protection 10A 250V AC Outlet Outlets Protector Surge Protected Batt. Protected 10A 250V AC 650VA AC Inlet Comm Port Fax/Modem Protection AC Inlet : Connection to mains Protector...
  • Page 18: Battery Test

    Operating manual CAUTION: When the load is connected to the surge protected output on the rear panel, the energy is taken directly from the mains therefore the loads will not have battery back-up if there is a mains failure. 5. Battery Test As soon as the UPS is connected to the mains, the battery will be charged independently whe- ther UPS is switched on or not.
  • Page 19: Interfaces

    Operating manual 5. If the battery is fully charged, the UPS will work in battery mode for 3 seconds. The red LED will be off. The beha- viour of the green LED and the buzzer are in accordance with the battery mode with normal voltage. 6.
  • Page 20: Maintenance

    Operating manual The following diagram explains the corresponding function of every pin of RS232: 7. Maintenance This UPS does not require any maintenance by the user. The typical lifetime of a battery is 4 years at a room temperature of 25 °C. Regularly check the unit's residual capacity time to ensure that it is sufficient, at least once every 12 months.
  • Page 21 Operating manual 7 - Assuming that the old batteries are fully charged. Use the same precautions you would use when handling a new battery. Do not short battery terminals with a cable or tool! Batteries contain lead. Many areas have regulations about disposing of used batteries. Please dispose of old batteries properly.
  • Page 22: Storage

    Operating manual 7.2 Storage For long time storage in moderate climates, the batteries should be charged for 8 hours every three months. Repeat every two months in high temperature locations. 1. Connect the UPS to socket outlet with earthing contact or install the types for fixed connection according to section 2.3 of this manual at an appropriate source.
  • Page 23: Technical Data

    Operating manual 9. Technical Data 945014.066 REV: 14/03/01...
  • Page 24: Battery Backup Times

    Operating manual 10. Battery Backup Times Desk Power 300: min. Load Desk Power 500: min. Load Desk Power 650: min. Load REV: 14/03/01 945014.066...
  • Page 25: Registration Form

    Please fill out this form as completely as possible. None of the fields are required but the information you provide will help us make our service better suited to your needs. The information you enter below will never be used outside of CHLORIDE POWER PROTECTION. Customer Information...
  • Page 26 Operating manual REV: 14/03/01 945014.066...
  • Page 27: Chloride Address

    Operating manual CHLORIDE WORLD HEADQUARTERS GERMANY Chloride Power Protection Masterguard George Curl Way Schallershofer Str. 141 Southampton D-91056 Erlangen Hampshire, SO18 2RY Germany United Kingdom Telephone: +49 9131 9855 100 Telephone: +44 (0) 23 8061 0311 Facsimile: +49 9131 9855 270 Facsimile: +44 (0) 23 8061 0852 info@masterguard.de...
  • Page 28 Facsimile: +44 (0) 23 8061 0852 Facsimile:+971 (4) 881 4518 .sales@chloridepower.com Oneac UK Latin America 18 & 20 Blacklands Way Chloride Power Protection Latin America Abingdon Business Park Rua Arizona 1349 Abingdon Brooklin Novo Oxfordshire, OX14 1DY Sao Paulo CEP 04567-002...

This manual is also suitable for:

Desk power 650Desk power 500

Table of Contents