Summary of Contents for Chloride Desk Power Plus 1000
Page 1
CHLORIDE POWER PROTECTION www.chloridepower.com Cert No FM 10144 This publication is issued to provide outline information only and is not deemed to form any part of any offer and contract.The company has a policy of continuous product development and improvement, and we therefore reserve the right to vary any information without prior notice.
Page 2
Desk Power Plus CHLORIDE Operating Manual POWER PROTECTION...
Page 5
Uninterruptible Power System Operating Manual Unterbrechungsfreie Stromversorgung Benutzer-Handbuch Sistema de Alimentación Ininterrumpida Manual de usuario Alimentation Sans Interruption Manuel Utilisateur Gruppo di continuità Manuale d’uso Sistema de Alimentação Ininterrupta Manual do Utilizator...
OPERATING MANUAL SAFETY NOTICES SYSTEM DESCRIPTION Front Panel Back Panel INSTALLATION AND OPERATION Inspection Placement Charging Computer Connection Modem/Phoneline Connection Serial Cable Connection DC Start Function Green Power Function Battery Replacement TROUBLE SHOOTING SPECIFICATION 10H52164PUMC REV. 1/11-2003...
IMPORTANT SAFETY INSTRUCTION SAVE THESE INSTRUCTIONS This manual contains important instructions for models Desk Power Plus 1000, Desk Power Plus 1400 that should be followed during installation and maintenance of the UPS and batteries. Safety Notices - This UPS uses voltage that may be hazardous. Do not attempt to disassemble the unit.
SYSTEM DESCRIPTION 1) Front Panel AC Mode: Load Level LEDs Fault LED Backup Mode: Battery Capacity LEDs AC Mode: Green Lighting Backup Mode: Power “ON/OFF” Green Flashing Switch 2) Back Panel Communication Port Cooling Fan Modem/Phone Line Surge Protection AC Output Circuit Breaker AC Input 10H52164PUMC...
Page 12
INSTALLATION AND OPERATION To install Desk Power Plus simply follow the instructions shown. Be aware that the Power Switch must be kept in the “ON” position, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure. 3) Inspection Remove the UPS from its package and inspect it for any damage that...
INSTALLATION AND OPERATION 5) Charging This unit is shipped from the factory with its internal battery fully charged, however some charge may be lost during shipping, and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours.
INSTALLATION AND OPERATION 7) Modem/Phoneline Connection Plug incoming internet line into the “In” socket at the back of the UPS . Use on more internet line cable and plug one end of the internet line cable to the “Out” socket at the back of the UPS. Plug the other end of the modem input socket as shown below.
INSTALLATION AND OPERATION 9) DC Start Function DC Start Function enables the UPS to be started up when AC utility power is not available and battery is fully charged . Just simply press the power switch to turn on the UPS. 10) DC Start function (cold start) This function allows the UPS to be turned on also when the AC mains is not present and the battery is completely charged.
Page 16
TROUBLE SHOOTING Symptom Remedy Possible Cause 1) Missing battery. 1) Charge battery up to 8 hours. No Led display 2) Battery defect. 2) Replace with the same on the front type of battery. panel. 3) Power switch is not 3) Press power switch for pressed at least 5 second.
Need help?
Do you have a question about the Desk Power Plus 1000 and is the answer not in the manual?
Questions and answers