Ice Maker Assy. - Model 501F - Sub-Zero 500 Series Technical Service/Training Manual

Hide thumbs Also See for 500 Series:
Table of Contents

Advertisement

Ice Maker Assy. - Model 501F

WARNING
Always disconnect electrical power to equip-
ment before attempting repairs.
CAUTION
Do not manually advance the ejector blades on
the modular ice maker.
The ice bucket is located in the top right freezer
basket (Figure 2-35).
The ice maker is connected to the ice level arm by
a connecting rod (Figure 2-36).
When the ice bucket is removed, ice production
will stop. There is a tab on the rear left hand cor-
ner of the bucket that activates the ice maker
switch (Figure 2-36).
1. To access and remove the icemaker assy.,
remove the top right freezer basket which con-
tains the ice bucket.
2. Slide the connecting rod to the right, off of the
icemaker shut-off arm, allowing the ice level
arm to drop out of the way.
3. Remove the mounting screw at the bottom left
of the icemaker which secures the icemaker
bracket to the drain trough enclosure.
4. Extract the two mounting screws at the top
rear, above the icemaker mold.
5. Pull the icemaker assy. forward and disconnect
the electrical leads from the icemaker.
COMPONENT INFORMATION
Models 501F
Freezer Basket Assy.
Figure 2-35. Ice Bucket
Connecting Rod
Figure 2-36. Icemaker Area
2-13
Ice Bucket
Screws
Fill Tube Heater
Ice Level Arm
Drain
Tube
Heater