Switch with the freezer door open.
SWITCH
There is continuity between pins 1 and 4.
There is no continuity between pins 1 and 3, 1 and 2.
2.5 Bimetal test
With the bimetal disconnected from the mains, using the digital multimeter set to the continuity scale to measure
the following points:
Bimetal wih closed contacts
The bimetal will show continuity between its terminals
if it is exposed to temperatures bellow -6°C, within a
variation of ± 4°C from that reference value.
This document cannot be reproduced or passed to third parties without authorization of Electrolux do Brasil S.A..
Switch with the refrigerator door open.
SWITCH
There is continuity between pins 1 and 2.
There is no continuity between pins 1 and 3, 1 and 4.
Bimetal with open contacts
The bimetal will not show continuity between its
terminals if it is exposed to temperatures above +25°C,
within a variation of ± 3°C from that reference value.