2.9.10 To remove the Reflecting Gutter:
• Unplug the connectors of the fuse-bimetal circuit and the resistance.
• Pull the evaporator locks to release the reflecting gutter.
2.9.11 To replace the fuse-bimetal circuit:
• Carefully turn the evaporator from the right to the left,
• Using a cutting pliers, remove the four plastic fasteners
as shown in the picture bellow.
that fix the fuse-bimetal circuit to the evaporator.
INSTALL THE NEW FUSE-BIMETAL CIRCUIT TAKING CARE TO POSITION IT THE SAME
WAY THE ORIGINAL CIRCUIT WAS POSITIONED. FIX THE NEW CIRCUIT WITH PLASTIC
FASTENERS CUTTING OFF THE EXCESS.