2.3 Timer

With the timer disconnected from the mains, measure with the help of the digital multimeter set to the continuity
scale. Turn the timer cam with the help of a screwdriver until hearing the first click and then measure.
Timer at defrost
There is continuity between pins 1 and 2.
There is no continuity between pins 1 and 4.
Turn the timer cam with the help of a screwdriver until
hearing the first click and then measure.

2.4 Switch test

With the switch disconnected from the mains. Check with the help of the digital multimeter set to the continuity
scale, the following points:
Switch with the two doors closed.
SWITCH
There is continuity between pins 1 and 3.
There is no continuity between pins 1 and 4, 1 and 2
This document cannot be reproduced or passed to third parties without authorization of Electrolux do Brasil S.A..
Timer turning on the compressor / motofan
There is continuity between pins 1 and 4.
There is no continuity between pins 1 and 2.
With the timer disconnected from the mains, measure
the timer motor with the digital multimeter set to the
ohmic resistance scale.
Switch with the two doors open.
SWITCH
There is continuity between pins 1 and 2, and 1 and 4.
There is no continuity between pins 1 and 3.