6.1.2 Defrost Bimetal registering a temperature less than -6
case of a power failure happening before the product has achieved a temperature above +25
defrost bimetal).
Accumulates 8 hours, considering the time
accumulated befor the turn off
Pause (10min)
(dripping with the resistances
already turned off)
6.1.3 During the continuous operation of the refrigerator
Accumulates 8 hours
of compressor operation
Pause (10min)
(dripping with the resistances
already turned off)

6.2 Compensation in Case of Power Failure

In case of power failure, the product will behave according to the following conditions once the power returns.
6.2.1 Defrost Bimetal registering a temperature equal to or above +25
The product will restart operation according to the procedure in item 6.1.1.
6.2.2 Defrost Bimetal registering a temperature lesser than -6
The product will preserve the same adjustment configuration it has before the power failure. The defrost will happen
according to item 6.1.2.
ELECTROLUX DO BRASIL S.A.
Rua Ministro Gabriel Passos, 360
Caixa Postal 16201 CEP 81 520900
Curitiba Paraná Brasil
Tel/Fax (041) 371 7000
http://disc.electrolux.com.br
Customer Care Center
Elaboration: Service Engineering
July/2004
Revision 0
This document cannot be reproduced or passed to third parties without authorization from Electrolux do Brasil S.A.
º
º
C (±4
C) when the refrigerator is turned on (in the
Defrost (up to +25ºC in the
Bimetal)
Defrost (up to +25ºC in the
Bimetal)
º
C
º
C
10
º
º
C (3
C) in the