Hameg HM 8131-2 Manual page 55

Programmable 15 mhz function generator
Hide thumbs Also See for HM 8131-2:
Table of Contents

Advertisement

Input via the button group
The simplest method to input parameters directly and exactly is
via the button group
(keyboard). The value selected will be
stored after pressing the appropriate button Hz, kHz, MHz.
Erasing values is possible by pushing [ESC]
the unit button. The formerly entered value will be restored. In
case an illegal value should be entered an acoustical signal will
sound (if this signal was activated), any formerly entered value
will remain valid.
In this example the value 102.56 kHz is to be entered:
Fr. 102.56_
-val+
<cur>
1
2
3
4
"Push the following buttons of the keyboard
[.], [5], [6]. Then push the button kHz/V, the display will show:
Fr: 102.5600000 kHz
-val+
<cur>
The cursor is now below the first digit to the right of the decimal
point.
Entering a parameter via the keyboard will always
cause the cursor to be placed below the first digit
to the right of the decimal point. The instrument did not need
to calculate,
In the following example the value 10256.78 Hz is to be entered:
STOP
*SWEEP PARAMETERS*
Start Stop Time Log
1
2
3
4
"Push the following buttons of the keyboard in turn: [1], [0], [2],
[5], [6], [.], [7], [8]. Enter the number by pushing button Hz/mV.
The display will show":
Fr: 10.256780 kHz
-val+
<cur>
The instrument will change the value entered in Hz into kHz.
The cursor will not reside below the first digit to the right of the
decimal point.
However, if you now look at the Hz – display you
will notice that there was a 7 to the right of the
decimal point, the cursor will come below the same 7 in the
kHz – display.
STOP
Subject to change without notice
before pushing
6
10
5
7
8
9
in turn: [1], [0], [2],
6
8
5
10
7
9
Input via the menu pushbutton group
"Go to the basic menu using the keyboard
following display:"
Fr. 1.0000000 kHz
Sin
Tri
STOP
"Push button [1] of the keyboard
shown by pushing button kHz/mV."
TiPP
"Push button [FREQ] inorder to activate the frequencefunction.
The display will show the following":
11
Fr: 1.0000000 kHz
-val+
Below the display there are the menu buttons
and
correspond with the display function – val +. With the two
b
buttons below the – and + symbols the value indicated by the
cursor can be decreased resp. increased. The buttons
belong to the cursor function < cur > and move the cursor left or
right.
In the following example the value 102.56 kHz is entered:
FR: _1.0000000 kHz
-val+
a
b
"Push the button
in button group
c
move the cursor 2 positions to the left.
11
FR: 101.0000000 kHz
-val+
a
b
Now push the button
will now show:"
FR: 102.0000000 kHz
-val+
a
b
How to input numbers?

so you will get the
Sqr -->
g
e
f
and enter the value
<cur>

. The buttons
<cur>
d
c

below the symbol < and
<cur>
c
d
below the symbol + once. The display
b
<cur>
c
d
h
a
and
c
d
55

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents