Hameg HM 8131-2 Manual page 47

Programmable 15 mhz function generator
Hide thumbs Also See for HM 8131-2:
Table of Contents

Advertisement

Accuracy:
Temperature coefficient: ± 0.1 %/degree
Phase
Range:
Resolution:
Reference:
Jitter:
Accuracy:
Square wave:
Sweep (internal)
Internal sweep:
Ranges:
Sweep time:
Modulation
FSK/PSK:
Frequency range:
Trigger:
Minimum duration:
Delay:
Amplitude modulation
Source:
Modulation depth:
Bandwidth:
Carrier frequency:
Accuracy:
Internal modulation:
External modulation:
Gate:
Delay:
Input signal:
Trigger:
Frequency range:
Miscellaneous
LCD:
Memory card:
Subject to change without notice
± (1 % x offset voltage + 5 digits)
0 ... 359.9 degrees
0.1 degree
falling slope of sync signal
<25 ns
except square wave:
± ( 0.1 + frequ./Hz x 10 exp -
6) degrees
± (5 + frequ./Hz x 30 x 10 exp - 6)
degrees
for all signal types linear or
logarithmic
100 mHz up to max. signal
frequency limit
Start and stop frequencies are
selectable.
10 ms to 40 s continuously
variable or triggered (by external
signal, keyboard, interface)
all signal types, noise excluded
100 µHz up to max. frequency
by external signal
25 µs
typ. 10 us PSK, typ. 15 us FSK
internal or external
0 .. 100 %
DC - 20 kHz (–3 dB)
100 µHz to max. signal frequency
± (5 % of display + 2 %)
1 kHz sine
20 Hz .. 20 kHz
(asynchronous)
<150 ns
TTL level
(synchronous)
<500 kHz
Burst mode via ext. trigger or
interface.
2 x 20 characters, back-lighted
PCMCIA II format up to 1 MB.
Allows storage of up to 31 arbi-
trary functions 16k or up to 114
arbitrary functions 4k.
Arbitrary signal editor
incorporated.
Memories:
Control:
RS-232:
IEEE-488:
Dimensions (W x H x D): 85 x 75 x 365 mm
Weight:
Operating temperature:
Humidity:
Supply voltage:
Mains frequency:
Power consumption:
Safety class:
Accessories included
Power cord, Manual, Warranty document
Available additional accessories
HO831
Memoery Card 1 MB
HO86:
TXCO 5 x 10
(10 to +40 degrees C)
HO88-2:
IEEE-488 interface
HZ24:
1 set of attenuators 50 ohms with
3- /6-/10- and 20 dB
HZ33, HZ34: BNC to BNC cables
HZ42:
19" rack mount kit 2 units (75 mm)
HZ72-S/L:
double-shielded IEEE-488 cable, 1 or 1.5 m
Software FG8131 (optional)
This software enables simple control of the instrument as well as
the back up and restore of the unit settings on a file. It has a signal
creator to edit arbitrary data. An additional function is the ability
to transfer the signal data from a HAMEG oscilloscope via DDE
from the software SP107 (requires version 2.12 or higher).
This software could be downloaded at www.hameg.de.
(Specifications without tolerance limits are values typical of an
average production instrument)
Specifications
10 for control settings
1 for arbitrary signals via memory
card or interface.
Manually or via interface.
included
Option HO88-2
appr. 5 kg
0 .. + 40 degrees C
10 .. 90 % relative, no
condensation
115/230 V ±15%
50/60Hz
appr. 30VA
Class I IEC 61010-1/ VDE 0411
-7
, 0.5 ppm/degree
47

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents