Fault indicators

Error message
Over Flow
Max program
time
Clean filter
Clean condenser
Thermistor fault
15
Cause
• A micro switch is opened when a full conden-
sed water tank is detected. Detection begins 30
seconds after the programme starts. If the micro
switch
is open >30 seconds the programme cycle is
stopped.
• The programme cycle time exceeds 200 minutes.
The cycle is stopped and the programme is reset.
• High ambient temperature combined with low
heater output and low drying temperature causes
condensation to form.
• Poor condensing due to blocked external air.
• Indicated when the air flow and temperature do
not match.
• Displayed automatically every 100 cycles.
• Displayed if the machine has indicated "Clean
filter" twice in a row.
• Thermistor circuit open.
• Thermistor malfunction.
Action
• Check that the customer has emptied the tank and
restarted the machine.
• Clean hoses and check voltage and resistance of
drainage pump.
• Check that the float has not got "stuck" and check the
function of the micro switch.
• Tried spinning at a higher speed.
• Had the machine switched off for 30 minutes
before restarting.
• Good ventilation in the room.
• Ensure that the external air has free passage.
• Clean the filter.
• Clean condenser and filter.
• Clean other air passages.
• Check the thermistor.