Fault indications

The below faults are indicated in plaintext in LCD 2. The table shows the indication in all languages and
language variations.
LCD 2
Overflow, Over Flow, Överfyllnad,
Overfyldning, Overfylling,
Ylitulviminen, Trop-plein,
Reservoir legen, Traboccamento,
Desbordamiento, Пeрeлив вoды,
Überfüllt
Max Program Time, Max program
time , Maximal programtid, Maksimal
programtid, Maks programtid, Max
ohjelma-aika, Durée maxi prog., Tijd
overschreden, Tempo max. progr.,
Duración máx prog, Пpeвышeниe
вpeмeни, Max. Programmzeit
Thermistor fault, Thermistor
Fault, Thermistor fault,
Termistorfel, Termostat fejl,
Termistor, Termistorivika, Défaut ,
Termistorfehler, Termistore , Fallo ,
Teрмистoр, Temp. sensor fout
Clean condenser, Rengör
kondensor, Rens kon.sator, Rens
kon.sator, Puhdista lauhdutin,
Nettoyage condenseur, Reinigen
kondensor, Pulizia condensatore,
Limpiar condensador, Oчистить
кoндeнсaтoр, Kondenser reinigen
Clean Lint Filter, Clean Lint Filter,
Rengör filtret, Rengør fnugfilter, Rens
filter, Puhdista sihti, Nettoyage filtre,
Reinig filter, Pulizia filtro, Limpie
el filtro, Oчистить фильтp, Sieb
reinigen
After carrying out corrective actions as above, reset the fault indications by switching off the machine using
the main power switch.
Cause
A micro switch, opening, for
detection of full, condensing
water container. Detection shall
start 30 sec after a program is
started. If the micro switch is
opened > 30 sec the program
cycle should be stopped and
cleared.
The cycle time exceeds 200
minutes. The cycle interupts
and the programme is cleared.
High ambient temperature
combined with low element
output and low drying
temperature leads to
condensation formation.
Poor condensation due to
blocked external air
1) The circuit for the thermistor
is open.
2) The thermistor is faulty
1) Indicated for each 100 cycle.
2) Indicated if the machine has
indicated "Clean lint filter" 2
times.
Indicated when air circulation
and temperature are incorrect
Action
Check if the customer has:
• Emptied the tank and restarted the machine
Service action:
• Clean hoses and check voltage and resistance in the
drain pump.
• Check that the float has not got "stuck" and check the
function of the micro-switch.
Check if the customer has:
• Tried spinning at a higher speed
• Has the machine switched off for 30 minutes before
restarting
• Good ventilation in the room
Service action:
• Ensure that the external air has free passage.
Service action:
Check the thermistors function. If needed, replace it.
Check if the customer has:
• Cleaned the condensor and filter
• Cleaned other air ducts
Check if the customer has:
• Cleaned the filter
Service manual TD60
15