ZyAIR B-5000 User's Guide
TEST ITEM
High Temperature
Operation
Low Temperature
Operation
High Temperature
High Humidity
Temperature
Recycle
ESD
G-6
Chart G-9 INSPECTION COSMETIC AND FUNCTION
TEST CONDITION
Temp.
+70 Deg. C
Storage
24 hours
Test
Operation mode in the chamber
Spec.
The same as +25 Deg. C
Temp.
-20 Deg. C
Storage
24 hours
Test
Operation mode in the chamber
Spec.
The same as +25 Deg. C
Spec.
The same as +25 Deg. C
Temp.
+40 Deg. C
Humidity
95%RH (non-condensing)
Storage
72 hours
Test
Operation mode in room temperature 4
hours after the storage
The same as +25 Deg. C
Spec.
Temp.
+20→0→-20→0→+20→+40→+60→
Cycle
+40→+20
Test
Operation in the chamber 1 hour after
arriving at the test temperature
Discharge
±15KV (Each polarity 10 times)
By Air
Discharge
±8KV (Each polarity 10 times)
By
Contact
CRITERIA
No Damage In
Cosmetics Or Error In
Function
No Damage In
Cosmetics Or Error In
Function
No Damage In
Cosmetics Or Error In
Function
No Damage On
Electrical Or Error In
Function
No Damage On
Electrical
Performance