false alarm control technology (FACT II)

Your system offers FACT
repetitive trigger sequences due to a faulty sensor or environmental
conditions such as thunder, jackhammers, airport noise, etc.
Here's how it works: The alarm triggers three times. If the same sensor
is triggering the alarm and the first and the third triggers are within 60
minutes of each other, FACT
false alarms. After the third trigger, FACT
sensor (along with any other sensors sharing the same zone) for 60
minutes.
If the bypassed sensor tries to trigger the system while it is being
bypassed, the 60-minute bypass period will start over. This ensures that
a sensor that continually triggers will remain bypassed.
Doors are covered by FACT
open door for three full cycles, the doors will be bypassed until the trig-
II
ger ceases. FACT
is programmable. See the Programming Options
section of this guide.
n n o o t t e e : : Arming and disarming the system does not reset this function! The
only way to reset a bypassed zone is for 60 minutes or to turn on the
ignition. If testing your system, it is important to remember that the FACT
II programming can cause zones to be bypassed and appear to stop
working. If you wish to clear the FACT II memory, turn the ignition key on.