Test Run - Mitsubishi Electric Jet Towel JT-MC106G-W-NA Installation Manual

Hand dryer
Hide thumbs Also See for Jet Towel JT-MC106G-W-NA:
Table of Contents

Advertisement

Available languages

Available languages

Test Run

Step
Check the power supply
1
voltage
Turn the ground fault circuit
2
interrupter on.
Turn the sensor switch is "ON".
3
(page 4)
Insert your hands to check if air is
4
being blow. (page 4)
Turn the heater switch "ON".
5
(page 14)
6
The maintenance light and heater light turn off after about 10 seconds. When the sensor switch or heater switch are
pressed again, the lights in the display section turn back on in the state where the settings have been made.
Caution
If the power light flashes, turn the breaker "OFF", check that power light is off, and then wait for 1 minute before
switching the breaker back "ON".
What to check for
Is the proper power being used?
(JT-MC106G-W-NA type:
Input Power: 120 Vac Single-phase
Incorrect power supply may cause malfunctions or low
wind power.
Are any lights in the display on?
Is the air blowing?
Is warm air blowing?
( Even if the heater switch is "ON", the heater may not operate if
it is used continually.)
As the heater is a simple heater, the air may not feel so
warm if the room temperature is low (68 F (20 C) or below).
Is the unit mounted securely without any vibration or abnormal
noises?
NA 12