6) The display shows ongoing error.
Note: 1. The display shows up to eight errors from the latest error.
2. If there is no error log, the display shows "- -".
3. Ongoing errors appear from the smallest error code, not from the latest error.
[h] RESETTING ERROR LOG
1) Press and hold the lock switch and portion control switch together, and turn on the
operation switch.
2) Error log is reset.
[i] REDUCING COMPRESSOR STARTING TIME
1) Press and hold the lock switch, and turn on the operation switch.
2) The display shows the model number, and the compressor starts running.
Note: The compressor startup delay time is reduced from 5 minutes to 2 minutes.
[j] RESETTING COMPRESSOR OPERATING HOURS
1) Press and hold the drain switch, lock switch and portion control switch together, and turn
on the operation switch.
2) The display shows "FA" and then the model number.
3) The compressor operating hours are reset.
4) Turn off the operation switch.
Note: Be sure to turn off the operation switch once, otherwise malfunction may occur.
37
Operation SW
Operation SW
Operation SW