Flush Water Valve - Hoshizaki DCM-60KE Service Manual

Cubelet ice dispenser
Hide thumbs Also See for DCM-60KE:
Table of Contents

Advertisement

6) Install the new valve.
7) Assemble the removed parts in the reverse order of which they were removed.
8) Open the water supply tap.
9) Plug in the ice dispenser.
10) Check for water leaks.
11) Refit the panels in their correct position.

10. FLUSH WATER VALVE

1) Move the ice making switch to the "OFF" position.
2) Press the drain switch on the control panel. The display illuminates "DRAIN" during the 1
minute drain cycle.
3) Unplug the ice dispenser, and close the water supply tap.
4) Remove the panels.
5) Remove the clamp and disconnect the hose from the flush water valve.
Note: Water may still remain inside the evaporator. Be sure to drain the water into the
drain pan.
6) Disconnect the terminals from the flush water valve.
7) Remove the flush water valve from the bracket.
8) Remove the drain pipe from the flush water valve.
9) Connect the drain pipe to the new flush water valve, and place the valve in position.
10) Connect the hose to the flush water valve, and secure it with the clamp.
11) Pour water into the reservoir, and check for water leaks on the flush water valve.
12) Open the water supply tap.
13) Plug in the ice dispenser.
14) Check for water leaks.
15) Push the drain switch, and make sure water is flushing.
16) Refit the panels in their correct position.
60

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcm-120keDcm-120ke-pDcm-60ke-p

Table of Contents