Displaying Electronic Control Card Parameters On The Boiler Display ("Info" Mode) - Baxi ECO 3 Instructions Manual

High efficiency wall-mounted gas-fired boilers
Hide thumbs Also See for ECO 3:
Table of Contents

Advertisement

20. dISplayInG paRaMEtERS On tHE dISplay ("InfO" MOdE)
Proceed as follows to display boiler parameters on the front panel display:
iMportant: the following operations (figure 14), it has to be carried out in fast sequence in a short time (~ 4 seconds)
without making any break during the steps:
1) with the control knob (
2) quickly turn control knob clockwise through about a
3) again turns the control knob fully anti-clockwise to it minimum value
4) then set back the control knob to it original position.
Figure 14
note: in "inFo" mode, the display (4 - figure 1) alternates between the message "a00" and ch temperature.
turn the control knob (
a00: domestic hot water output temperature (°C);
a01:
outdoor temperature (in °C) with outdoor sensor probe connected;
a02:
the value (%) of the modulator current (100% = 230 mA NATURAL GAS - 100% = 310 mA LPG);
a03:
heat output (%) power range (max R);
a04:
central heating water output setpoint temperature (°C);
a05:
central heating water output temperature (°C);
a07:
valve (µA) of the ionization current.
note: program lines from a06 - a08 - a09 are not used.
"INFO" function remains active for 3 minutes. To exit "INFO" function before this time repeat the operation as described
in points 1...4 or cutting OFF the power supply to the boiler.
instructions pertaininG to the
) in any position turns it fully anti-clockwise to the minimum value;
) to display the following informations:
instaLLer
16
/
turn;
1
4
924.674.3 - GB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eco3

Table of Contents