Displaying Electronic Control Card Parameters On The Boiler Display ("Info" Mode) - Baxi PRIME HT 240 Installers And Users Instructions

Table of Contents

Advertisement

PRIME HT 240 - HT 1.240
Gas consumption at 15 °C
1013 mbar
PCI
Consumption at max. heat output
Consumption at min. heat output
Table 2d
PRIME HT 1.120
Gas consumption at 15 °C
1013 mbar
PCI
Consumption at max. heat output
Consumption at min. heat output
Table 2e
TABLE 3: SETTING PARAMETRES 608 AND 611
Counter clockwise
Boiler model
turns of screw
PRIME HT 330
PRIME HT 280
PRIME HT 240
PRIME HT 1.280
PRIME HT 1.240
PRIME HT 1.120
Table 3

17. DISPLAYING ELECTRONIC CONTROL CARD PARAMETERS ON THE BOILER DISPLAY ("INFO" MODE)

Proceed as follows to display boiler parameters or outdoor temperature on the front panel display.
1) Turn the control knob 6 (figure 1) fully anti-clockwise to it minimum value as shown in figure 21A.
2) Starting in this position, quickly turn control knob 6 twice consecutively clockwise through about a
in figure 21B.
NOTE: In "INFO" mode, the display (5 - figure 1) alternates between the message "A0" and DHW temperature about
every 5 seconds (figure 22).
G20 - 2H - 20 mbar
G31 - 3P - 37 mbar
34.02 MJ/m
3
2.61 m
/h
3
0.74 m
/h
3
G20 - 2H - 20 mbar
G31 - 3P - 37 mbar
34.02 MJ/m
3
1.31 m
/h
3
0,42 m
/h
3
Parameter
%
(V)
Gas G20
Gas G31
3
50
4
55
2
50
3
50
2
55
/
40
3
4
Figura 21A
Figura 21B
INSTRUCTIONS FOR THE INSTALLER
46.3 MJ/kg
1.92 kg/h
0.54 kg/h
46.3 MJ/kg
0.96 kg/h
0,31 kg/h
608
Parameter
611
rpm
Gas G20
Gas G31
35
4100
3500
35
4400
4000
35
4300
4000
35
4100
3500
35
4500
4000
40
4000
3350
25
/
turn as shown
1
4