Technical Data - Rangemaster Professional+ 100 FX Dual Fuel User's Manual & Installation Instructions

Table of Contents

Advertisement

9. Technical Data

THE COOKER IS CATEGORY: Cat II 2H3+ .
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: GB, IE.
Connections
Gas (Rp ½ at rear right-hand side)
Natural gas
Butane
Propane
See the appliance badge for test pressures.
Dimensions
Overall height
Overall width
Overall depth
Hotplate clearance
Refer to 'Positioning the Cooker' .
Ratings
Hotplate
Wok burner
Large burner
Medium burner
Small burner
* The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for
Natural gas. For LPG conversion the bypass screws must be screwed all the way down.
Oven Efficiency
Ovens
Maximum output at 230 V
Energy efficiency class on a scale of A (more efficient) to G (less efficient)
Energy consumption based on standard load
Oven volume (litres)
Size
Time to cook standard load
Surface area of the grid
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.): 4.44 kW.
20 mbar
29 mbar
37 mbar
Natural Gas 20 mb
Bypass
Screw*
57
3.5 kW
40
3.0 kW
32
1.7 kW
28
1.0 kW
ArtNo.105-0008 - Technical data - 90 induction - Elan
minimum 905 mm
994 mm
604 mm excluding handles; 642 mm including handles
Injector
internal 78
external 126
134
109
75
Left-hand Oven
Multi-function
0.99 kWh
41 minutes
1400 cm
29
Electric
230/400 V 50 Hz
maximum 930 mm
650
L.P. Gas
3.5 kW (246 g/h)
3.0 kW (210 g/h)
1.7 kW (119 g/h)
1.0 kW (70 g/h)
Right-hand Oven
Multi-function
2.5 kW
A
0.79 kWh
74
Large
Medium
44 minutes
1056 cm
2
Injector
internal 53
external 82
87
68
51
1.84 kW
A
54
2