Burner and nozzle specifications

Table 1
Burner
Fast (R)
Semi Fast (S)
Auxiliary (A)
Supply pressures
*
At 15°C and 1013 mbar-dry gas
Natural P.C.S. = 37.78 MJ/m³
S
S
A
7HPK 644 D GH X /HA
7HPKQ 644 D GH /HA
4
Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nomin.
Reduc.
157
3.00
1.00
132
1.90
0.80
110
1.00
0.50
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
S
R
A
7HPK 755 D GH X/HA
7HPKQ 755 D GH /HA
Checking the tightness of the connection
! When the installation process is complete, check the
pipe fittings for leaks using a soapy solution. Never use a
flame.
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet pipe (in order
to comply with current national regulations).
Natural Gas
Adjusting the burner's
(G20 / 20 mbar)
primary air
Nozzle
Flow*
1/100
l/h
(mm)
(G20)
125
286
100
157
72
95
20
17
25
S
R
A
(mm)
4.7
2.6
2