No electrical power supply is required for
the gas control to operate. However, a
240V A.C. power supply is needed for the
fan/blower operation.
Caution: Ensure that the wires do not
touch any hot surfaces and are away
from sharp edges.
Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes:
1)
Checking the operating pressure (see data label)
2)
If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize.
3)
Check for proper draft.
CAUTION: Any alteration to the product that causes sooting or carboning that results in damage to the unit is not the
responsibility of the manufacturer and will not be covered by the warranty.
Masport F33-1 Freestanding Gas Stove
WIRING
WARNING: Electrical Grounding
Instructions
This appliance is equipped with a three
pronged (grounding) plug for your pro-
tection against shock hazard and
should be plugged directly into a prop-
erly grounded three-prong receptacle.
Do not cut or remove the grounding
prong from this plug.

FINAL CHECK

INSTALLATION
CAUTION:
Label all wires prior to discon-
nection when servicing controls.
Wiring errors can cause im-
proper and dangerous opera-
tion.