Outdoor Unit - Haier H2SM-(9+12)HEK03/R2 Service Manual

On/off ek-series
Hide thumbs Also See for H2SM-(9+12)HEK03/R2:
Table of Contents

Advertisement

5.4.2 Outdoor Unit

B25°C/50°C=3450K±1%
Temp.((°C))
-30
-29
-28
-27
-26
-25
-24
-23
-22
-21
-20
-19
-18
-17
-16
-15
-14
-13
-12
-11
-10
-9
-8
-7
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
H2SM-(9+12)HEK03/R2
Ambient Sensor, A and B Pipe Sensor
58.77
55.73
52.87
50.17
47.62
45.22
42.96
40.82
38.80
36.90
35.09
33.39
31.78
30.26
28.82
27.46
26.17
24.94
23.79
22.69
21.65
20.66
19.72
18.84
17.99
17.19
16.43
15.71
15.02
14.37
13.75
13.16
12.60
12.07
11.56
11.07
10.61
10.17
9.754
9.354
8.974
8.611
8.264
7.934
7.618
7.317
26
Funcitions and Control
60.94
57.75
54.75
51.93
49.27
46.76
44.39
42.16
40.05
38.06
36.19
34.41
32.74
31.15
29.65
28.24
26.89
25.62
24.42
23.28
22.20
21.18
20.21
19.29
18.42
17.59
16.81
16.06
15.35
14.68
14.04
13.43
12.85
12.30
11.78
11.28
10.80
10.35
9.921
9.511
9.120
8.747
8.392
8.053
7.729
7.421
Domestic Air Conditioner
63.18
59.84
56.70
53.74
50.96
48.34
45.87
43.54
41.34
39.26
37.31
35.46
33.71
32.07
30.51
29.03
27.64
26.32
25.07
23.89
22.77
21.72
20.71
19.76
18.86
18.00
17.19
16.42
15.69
14.99
14.33
13.70
13.11
12.54
12.00
11.49
11.00
10.53
10.09
9.669
9.268
8.885
8.521
8.173
7.841
7.525

Hide quick links: