5.3 Function of Main Thermistor

Note: A:Outdoor suction temperature sensor
The outdoor heat exchanger thermistor is used for controlling target discharge temperature.
Suction
The system sets a target discharge temperature according to the outdoor and indoor heat
Temperature
exchanger temperature, and controls the electronic expansion valve opening so that the
Sensor
target discharge temperature can be obtained.
Exhaust
The discharge pipe thermistor is used for controlling temperature of the discharge pipe.
Temperature
If the temperature of discharge pipe (used in place of the inner temperature of the
Sensor
compressor) rises abnormally, the operating frequency drops or the operation halts.
1.The indoor heat exchanger thermistor is used for controlling target discharge
temperature.
The system sets a target discharge temperature according to the outdoor and indoor heat
exchanger temperature, and controls the electronic expansion valve opening so that the
Indoor heat-
target discharge temperature can be obtained.
2.The indoor heat exchanger thermistor is used for preventing freezing.During the cooling
Sensor
operation, if the temperature drops abnormally, the operating frequency becomes lower,
then the operation halts.
3.The indoor heat exchanger thermistor is used for anti-icing control.During the cooling
operation, if the heat exchanger temperature in the room where operation is halted
becomes -1°C, it is assumed as icing.
H2SM-(9+12)HEK03/R2
B: Exhaust temperature sensor
C: Indoor heat-exchange sensor