Maintenance; Motor; Dirt Receptacle; Disposable Bag & Filter - Cyclo Vac Tradition E100 Owner's Manual

Cyclo vac e series and dl series central vacuum system
Table of Contents

Advertisement

Motor

Please note that Cyclo Vac motors do not require lubrication. Each motor
contains two carbon brushes which will wear normally, and may eventually require
replacement. For warranty purposes, this should be done by an authorized service
center. Brush life is affected by the number of hours used, frequency of start-ups
and shut-downs, humidity, altitude, and temperature. In order to avoid damage
to the motor itself, brushes should be replaced before they are completely worn
out. We therefore recommend that you have your unit and motors inspected by a
service center every 5-6 years.

Dirt Receptacle

Occasional maintenance of the dirt receptacle is necessary to ensure constant,
lasting performance. We recommend that it be emptied at least every season,
depending on frequency of use. To empty the dust receptacle, fi rst disconnect your
vacuum cleaner from its power source. Then release the two clamps, lower and
empty the recipient, then replace it and seal by refastening the metal clamps.
Disposable Bag & Filter
Change the bag when the one in place
is full. Frequency will depend on the use
of the unit.
Line-up the notches in the bag collar
with the tabs on adaptor (fi gure 17).
Insert the bag as far as the retention
ring, to ensure airtightness.
The disc-shaped fi lter (fi gure 18),
located between the dust bag and the
motor, should be changed once for
every three bags (45 hours of use), or
more often as needed.
Use only genuine Cyclo Vac replacement
bags. Failure to do so could void the
warranty on your vacuum unit.
24
(Except E100 Model)
retention
ring

Maintenance

(E100 Model Only)
Type 3 Bag
Part Number: TDSAC43C
fi gure 17
fi gure 18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tradition dl seriesTradition e series

Table of Contents