Decrease In Suction Strength - Cyclo Vac Tradition E100 Owner's Manual

Cyclo vac e series and dl series central vacuum system
Table of Contents

Advertisement

Troubleshooting
P
ROBLEM
Decrease in suction
strength
28
P
OSSIBLE CAUSE
Dirt recipient / Bag is full Empty dirt recipient /
Dirt recipient is not
properly attached
Filters need cleaning /
replacing
Motor guard screen is
blocked
Open vacuum inlet
Exhaust line is clogged
Troubleshooting
C
ORRECTIVE ACTION
change bag (see page
25).
Check clamps holding
dirt recipient, to make
sure they are tight, and
dirt recipient is aligned.
Remove, shake and/or
wash fi lters or replace
them (depending on
model) before reinstalling
them in the unit (see
page 26).
Remove fi lters, and
check the guard screen
(which separates the
motor from the fi ltration
compartment) for
blockage. Ensure fi lters
are always properly
installed, to prevent this
problem from happening
again.
Close all vacuum inlets
not in use.
Verify that no object is
blocking the exhaust.