"Ω×1"
1
Gy
OFF
Br
R
ON
Gy
Br
R
EAS00730

SWITCHES

"0"

CHECKING SWITCH CONTINUITY

Check each switch for continuity with the
pocket tester. If the continuity reading is incor-
rect, check the wiring connections and if nec-
essary, replace the switch.
CAUTION:
@
Never insert the tester probes into the cou-
pler terminal slots 1. Always insert the
probes from the opposite end of the cou-
pler, taking care not to loosen or damage
the leads.
NOTE:
@
• Before checking for continuity, set the pocket
tester to "0" and to the "Ω × 1" range.
• When checking for continuity, switch back
and forth between the switch positions a few
times.
The terminal connections for switches (e.g.,
main switch, engine stop switch) are shown in
an illustration similar to the one on the left.
The switch positions a are shown in the far
left column and the switch lead colors b are
shown in the top row in the switch illustration.
NOTE:
@
"
between switch terminals (i.e., a closed circuit
at the respective switch position).
The example illustration on the left shows
that:
There is continuity between red and brown
when the switch is set to "ON".
7 - 2
ELEC
SWITCHES
Pocket tester
YU-03112
" indicates a continuity of electricity
+