4-Burner Cooktop Models
with 15,000 BTU/HR Burner on Right Front
(See rating plate on bottom of appliance)
BURNER OUTPUT RATING:BTU/HR
Natural Gas 4"W.C.P.
BURNER
BTU RATE
RR
6,000
LR
11,000
LF
9,100
RF
15,000
BURNER OUTPUT RATING:BTU/HR
LP (PROPANE) GAS 10" W.C.P.
BTU RATE
BURNER
RR
6,000
LR
9,100
LF
8,100
RF
13,000
III
II
6. Return the natural gas orifices to the plastic
bag along with these instructions for future
conversion back to natural gas.
Caution: When attaching the burner base to
glasstop unit, tighten to 10 in./lbs max torque.
Overtightening will cause damage.
7. Replace the burner bases, spark igniters,
heads, caps, and top grates.
ORIF. SIZE
1.18 Nmm
1.61 Nmm
1.50 Nmm
1.93 Nmm
ORIF. SIZE
.79 Lmm
.90 Lmm
.84 Lmm
1.04 Lmm
GEA00750
I
X
GEA00751
GEA00754
– 7 –
4-Burner Cooktop Models
with 9,100 BTU/HR Burner on Right Front
(See rating plate on bottom of appliance)
BURNER OUTPUT RATING:BTU/HR
Natural Gas 4"W.C.P.
BURNER
BTU RATE
RR
6,000
LR
9,100
LF
9,100
RF
9,100
BURNER OUTPUT RATING:BTU/HR
LP (PROPANE) GAS 10" W.C.P.
BTU RATE
BURNER
RR
6,000
LR
8,100
LF
8,100
RF
8,100
II
II
5-Burner Cooktop Models
BURNER OUTPUT RATING: BTU/HR
Natural Gas 4" W.C.P.
BURNER
BTU RATE
RR
6,000
CR
6,000
LR
9,100
LF
11,000
RF
15,000
BURNER OUTPUT RATING: BTU/HR
LP (Propane) Gas 10" W.C.P.
BURNER
BTU RATE
RR
6,000
CR
6,000
LR
8,100
LF
9,100
RF
13,000
ORIF. SIZE
1.18 Nmm
1.50 Nmm
1.50 Nmm
1.50 Nmm
ORIF. SIZE
.79 Lmm
.84 Lmm
.84 Lmm
.84 Lmm
GEA00752
I
II
GEA00753
ORIF. SIZE
1.18 Nmm
1.18 Nmm
1.50 Nmm
1.61 Nmm
1.93 Nmm
ORIF. SIZE
.79 Nmm
.79 Nmm
.84 Nmm
.90 Nmm
1.04 Nmm
GEA00755

Hide quick links: