Chapter 3 Troubleshooting - Allied Telesis AT-FS201 Installation Manual

Fast ethernet switches
Hide thumbs Also See for AT-FS201:
Table of Contents

Advertisement

Chapter 3
Troubleshooting
Follow the guidelines below to test and troubleshoot the installation in the
event a problem occurs.
Note
Whenever the speed and/or duplex mode are changed during or after
power ON, power OFF then power back ON the switch to load the new
configuration.
If the PWR LED is OFF, do the following:
If the switch is installed on a desktop, check to be sure that the power
adapter is securely connected to a power outlet and that the power
adapter cable is securely connected to the back of the switch.
If the switch is installed in an AT-MCR12 chassis, check that the unit
is fully seated in the slot.
Verify that the power outlet has power by connecting another device
to it.
Try using another power adapter.
If the LNK/ACT LED for the twisted pair port is OFF, do the following:
Check that the end-node connected to the port is powered ON and is
operating properly.
Check that the twisted pair cable is securely connected to the twisted
pair port on the switch and on the end-node.
Check to be sure that the end-nodes connected to the switch are
operating at the same duplex mode.
Make sure that the twisted pair cable does not exceed 100 meters (328
feet) and that you are using a Category 3 or better cable for 10Base-T
operation or a Category 5 or better cable for 100Base-TX operation.
15