SAFETY INSTRUCTIONS

CHECKING FOR GAS LEAKS
Never test for leaks with a flame. Prior to first use
and at the beginning of each new season, you must
check for gas leaks.
Follow these steps:
1.Make soap solution by mixing one part liquid
detergent and one part water.
2.Turn off heat control valves, and then turn on gas
at source.
NATURAL GAS SAFETY
Your natural gas is designed to operate on
natural gas grill only, at a pressure of 4" water
column(1/4 psig or 1.75 kpa) regulated at the
pre-set supplied regulator. Check with your gas
utility for local gas pressure and with your local
municipality for building code requirements. If
your residential gas utility line pressure has not
been regulated to 7" W.C. contact your local gas
utility or gas grill dealer for professional
assistance.
Check with your gas utility or with local building
codes for instructions to install gas supply line,
or call a licensed and knowledgeable installer.
It is recommended that an "ON-OFF" shut off
valve be installed at the gas supply source;
outdoors after the gas line piping exits outside
the wall and before the quick-disconnect. In a
branch fuel line, it should be installed before the
3. Apply the soap solution to all gas connections.
Bubbles will appear in the soap solution if
connections are not properly sealed. Tighten or
repair as necessary.
4. If you have a gas leak that you cannot repair,
turn off the gas at the source, disconnect the
fuel line from grill and
grill dealer or gas supplier for professional
assistance.
gas line piping enters the ground indoors in an
accessible location near the supply line.
Pipe sealing compound or pipe thread tape of
the type resistant to the action of natural gas
must be used on all male pipe threads when
making the connection.
Disconnect your gas grill from its fuel source
when the gas supply lines are being tested at
high pressures by the gas company. This
appliance and its individual shut off valve must
be disconnected from the gas supply piping
system during any pressure testing of that
system at pressure in excess of ½ psi (3.5 kpa).
Turn off your gas grill when the gas supply is
being tested at low pressures by the gas
company. This appliance must be isolated from
the gas supply piping system by closing its
individual manual shut off valve during any
pressure testing of the gas supply piping system
at pressures equal or less than ½ psi (3.5kpa).