Table 9. Error Beep Codes Generated By Intel; Remote Management Module - Intel Server Board S5000PAL User Manual

Intel server board user guide
Hide thumbs Also See for Server Board S5000PAL:
Table of Contents

Advertisement

In addition to the beep codes above, additional beep codes are provided if an Intel
Remote Management Module is installed. The Intel
provides the following additional beep codes.

Table 9. Error Beep Codes Generated by Intel

Number of
Beeps
1
1-5-1-1
1-5-2-1
1-5-2-3
1-5-2-4
1-5-4-2
1-5-4-3
1-5-4-4
®
Intel
Server Board S5000PAL User's Guide
Reason for Beeps and Action to Take
Control panel CMOS clear has been initiated.
Processor failure. Reseat or replace the failed processor.
No processor is installed or the CPU 1 socket is empty. Reseat or replace
the failed processor.
Processor configuration error or CPU 1 socket is empty. Reseat or replace
the failed processor. In a two-processor system, make sure the processors
are identical.
Front-side bus select configuration error.
DC power unexpectedly lost.
Chipset control failure.
Power control failure.
®

Remote Management Module

®
Remote Management Module
®
51