Strobe White Balance Adjustment - Sony Cyber-shot DSC-P1 Service Manual

Digital still camera
Hide thumbs Also See for Cyber-shot DSC-P1:
Table of Contents

Advertisement

14. Strobe White Balance Adjustment

Adjust the white balance when the strobe light flashed.
Mode
Subject
Adjustment Page
Adjustment Address
Specified Value
Note 1: Perform "Flange Back Adjustment", "Light Level
Adjustment" and "Auto White Balance Adjustment"
before this adjustment.
Note 2: Perform this adjustment in the Flash adjustment box.
Note 3: Refer to "4. Preparing the Flash adjustment box". (See
page 5-7)
Note 4: Displayed data of page: F, address: 64, of the adjusting
remote commander.
F:XX:64
Note 5: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Note 6: Displayed data of page: F, address: 69, 6A of the adjusting
remote commander.
F:XX:69
F:XX:6A
XX XX
Note 7: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Switch setting:
1) FLASH ........................ ON
Checking method:
Order Page Address Data
1
0
01
01
2
5
F1
FF
3
D
63
40
4
5
6
90
00
6
6
91
00
7
6
92
00
8
6
93
60
9
6
6C
01
10
6
2C
01
11
6
01
79
12
7
01
44
13
STILL
Flash adjustment box (Note 3)
(1.0 m from the front of lens)
F
4D, 4E, 64, 69, 6A, 6B
Y level data: 64 to 98 (Note 4)
R-Y level data: FA to FF or 00 to 06
(Note 5)
B-Y level data: FA to FF or 00 to 06
(Note 5)
A/D integral value data: 0020 or
more (Note 6)
Displayed data
R-Y level data
B-Y level data
Displayed data
Displayed data
Page: F, address: 6A (Lower)
Page: F, address: 69 (Higher)
Procedure
Press PAUSE button.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-13)
Press PAUSE button.
Press PAUSE button.
Wait for 5 seconds.
Order Page Address Data
14
6
01
15
6
02
16
6
01
17
6
01
18
19
6
01
20
6
02
21
6
01
22
6
01
23
24
6
01
25
6
02
26
6
01
27
6
01
28
29
6
01
30
6
02
31
F
64
32
0
03
33
1
69
34
F
6A
Note 8: The adjustment data will be automatically input to page:
F, address: 4D, 4E, 64 and 69 to 6B.
Processing after Completing Adjustment:
Order Page Address Data
1
6
2C
2
6
93
3
6
01
4
6
6C
5
7
01
6
0
03
7
5
F1
8
D
63
9
10
0
01
5-24
Procedure
67
Press PAUSE button.
Check the data changes to
"01".
00
Press PAUSE button.
79
Press PAUSE button.
Wait for 1 second.
67
Press PAUSE button.
Check the data changes to
"01".
00
Press PAUSE button.
79
Press PAUSE button.
Wait for 1 second.
B9
Press PAUSE button. (Note 8)
Check the data changes to
"01".
00
Press PAUSE button.
79
Press PAUSE button.
Wait for 1 second.
67
PAUSE button.
Check the data changes to
"01".
Check that the Y level data
(Note 4) satisfies the specified
value.
02
Check that the R-Y, B-Y level
data (Note 5) satisfies the
specified value.
Check that the A/D integral value
data (Note 6) satisfies the
specified value.
Procedure
00
00
00
Press PAUSE button.
00
04
Press PAUSE button.
00
00
00
Press PAUSE button.
Release the data setting
performed at step 4.
(Refer to page 5-13)
00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cybershot dsc-p1

Table of Contents