1-2-2.

Initializing B, E, F, 7 Page Data

1. Initializing B, E, F, 7 Page Data
Note: If the B, E, F Page data has been initialized, "Modification
of B, E, F, 7 Page Data" and following adjustments need
to be performed again.
1) Modification of B, E, F, 7 page data
2) Video system adjustments
3) Camera system adjustments
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Initializing Method:
Order Page Address Data Procedure
1
0
01
01
2
B
00
00
3
6
03
09
4
6
00
2D
5
6
01
2D
6
6
02
7
2. Modification of B, E, F, 7 Page Data
If the B, E, F, 7 Page data has been initialized, change the data of
the "Fixed data-2" address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B, E, F, 7 Page data
Order Page Address Data Procedure
1
6
00
29
2
6
01
29
F
10 to FF
E
00 to FF
B
00 to FF
7
00 to FF
Press PAUSE button.
Press PAUSE button.
Check the data changes to "01".
Perform "Modification of B,
E, F, 7 page Data".
Press PAUSE button.

3. B Page Table

Note 1: Fixed data-1: Initialized data.
(Refer to "1. Initializing B, E, F, 7 Page Data")
Note 2: Fixed data-2: Modified data.
(Refer to "2. Modification of B, E, F, 7 Page Data")
Address Initial value
00
01 to FF

4. E Page Table

Note 1: Fixed data-1: Initialized data.
(Refer to "1. Initializing B, E, F, 7 Page Data")
Note 2: Fixed data-2: Modified data.
(Refer to "2. Modification of B, E, F, 7 Page Data")
Address Initial value
00 to FF
5-9
Remark
Fixed data-2
Fixed data-1 (Initialized data)
Remark
Fixed data-1 (Initialized data)

Hide quick links: