6. Picture Frame Setting
Mode
Subject
Measurement Point
Measuring Instrument
Specified Value
Note 1: Displayed data of the page 1 of adjusting remote
commander.
1:XX:XX
Setting method:
Order Page Address Data
1
0
01
01
2
5
F1
FF
3
D
63
40
4
5
6
7
0
03
18
8
1
9
0
03
22
10
1
11
0
03
00
12
5
F1
00
13
D
63
00
14
15
0
01
00
STILL
Color bar chart
(Color reproduction adjustment
frame)
Video terminal of A/V OUT jack
(75 Ω terminated)
Oscilloscope and TV monitor
A=B, C=D, E=F
XL or YL data
XH or YH data
Procedure
Press PAUSE button.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-13)
Adjust the zoom and the camera
direction, and set to the picture
frame to the specified position.
Mark the position of the picture
frame on the TV picture
monitor, and adjust the picture
frame to this position in
following adjustment using
"Color reproduction
adjustment frame".
Note down the XH and XL
data. (Note 1)
Note down the YH and YL
data. (Note 1)
Press PAUSE button.
Release the data setting
performed at step 4.
(Refer to page 5-13)
How to reset the zoom and focus when they deviated:
Order Page Address Data
1
6
90
2
6
91
3
6
92
4
6
93
5
6
6C
6
6
01
7
8
6
2C
9
6
01
Note 2: The data noted dowm at step 8 of "Setting method".
Note 3: The data noted dowm at step 10 of "Setting method".
Check on the oscilloscope
1. Horizontal period
A=B
B
A
2. Vertical period
E
Check on the TV monitor
Color bar chart picture frame
5-18
Procedure
XL
(Note 2)
XH
(Note 2)
YL
(Note 3)
YH
(Note 3)
01
79
Press PAUSE button.
Wait for 1 second.
01
00
Press PAUSE button.
C=D
C
D
Fig. 5-1-14
E=F
F
V
Fig. 5-1-15
TV monitor picture frame
Fig. 5-1-16