Specifications - Valor PORTRAIT 922ECN Installation & Operating Instructions Manual

Portrait decorative vented gas fireplace with coal effect fuel
Hide thumbs Also See for PORTRAIT 922ECN:
Table of Contents

Advertisement

Operating your fireplace for the first time.
When operating your new fireplace for the first time,
some vapors may be released due to the burning of
curing compounds used in the manufacture of the
appliance. They may cause a slight odor and could
cause the flames to be the full height of the firebox, or
even slightly higher, for the first few hours of operation.
It is also possible that these vapors could set off any
smoke detection alarms in the immediate vicinity.
Approvals and Codes
This appliance is certified to ANSI Z21.50b–2009/CSA
2.22b–2009 Vented Gas Fireplaces Standard for use in
Canada and USA.
The appliance complies with CSA P4.1-09 Testing
method for measuring annual fireplace efficiencies.
The installation must conform with local codes or, in
the absence of local codes with the National Fuel Gas
Code, ANSI Z223.1or the Natural Gas and Propane
Installation Code CAN/CGA-B149. Only qualified
licensed or trained personnel should install the
appliance.
Venting
This appliance must be connected to an approved
venting system.
Ratings
Altitude (Ft)
Input Max. (Btu/h)
Input Min (Btu/h)
Manifold pressure (in.w.c.)
Min. Supply pressure (in. w.c.)
Max. Supply pressure (in. w.c.)
*Tested to CGA - 2.17-91 High Altitude Standard in
Canada. In USA, installations may require deration
over 2000' —Check local codes.
Safety and Warning Information

Specifications

NG
LPG
0-4500 *
20,500
19,000
12,000
12,500
3.7
10.5
5
11
10.5
13
These vapors are quite normal on new appliances. We
recommend opening a window to vent the room. After
a few hours use, the vapors will have disappeared and
the flames will be at their normal height.
*High Altitude Installations
I nput ratings are shown in BTU per hour and are
certified without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to confirm.
For installations at elevations above 4,500 feet (1,370
m) in Canada, please consult provincial and/or local
authorities having jurisdiction.
electrical
The unit does not require an electrical power source.
Supply Gas
Model 922ECN is for use only with natural gas. Model
922ECP is for use only with propane gas. The supply
pressure must be between the limits listed above.
The supply connection is 3/8"NPT male thread. The
supply pipe connection is to a flexible connector at the
left hand side of the appliance.
5 5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Portrait 922ecp

Table of Contents