Operation; Generator Location; Surge Protection; Wireless Remote Start - Champion Category 5 46538 Owner's Manual And Operating Instructions

3500 peak watts / 3000 running watts wireless remote electric start portable generator
Table of Contents

Advertisement

Operation

Generator Location

Please consult your local authority. In some
areas, generators must be registered with
the local utility.
Generators used at construction sites may be
subject to additional rules and regulations.
This generator must have at least five feet of
clearance from combustible material. Leave
at least three feet of clearance on all sides of
the generator to allow for adequate cooling,
maintenance and servicing.
Place the generator in a well-ventilated area.
DO NOT place the generator near vents or
intakes where exhaust fumes could be drawn
into occupied or confined spaces. Carefully
consider wind and air currents when
positioning generator.

Surge Protection

CAUTION
Voltage fluctuation may impair the proper
functioning of sensitive electronic equipment.
Electronic devices, including computers and
many programmable appliances use
components that are designed to operate
within a narrow voltage range and may be
affected by momentary voltage fluctuations.
While there is no way to prevent voltage
fluctuations, you can take steps to protect
sensitive electronic equipment.
1.
Install UL1449, CSA-listed, plug-in
surge suppressors on the outlets feeding
your sensitive equipment.
Surge suppressors come in single- or
multi-outlet styles. They're designed to
protect against virtually all short-
duration voltage fluctuations.
2. Obtain an Uninterruptible Power
Supply (UPS) device.
Most UPS devices come with a
rechargeable battery between the
electronic equipment and power supply
source. The device buffers the voltage
and protects against virtually all short-
duration voltage fluctuations.
Rev 46538-20100614 E

Wireless Remote Start

Wireless remote starting is only possible
within 80 feet of the generator.
Do not attempt to adjust the carburetor
choke. The remote system will automatically
close and open the choke.
1.
Make certain the generator is on a flat,
level surface.
2. Turn off all electrical loads connected to
the generator. Never start or stop the
generator with electrical devices plugged
in and turned on.
3. Turn the fuel valve to the "On" position.
4. To start the engine, press and release
the START button on the handheld
remote control device. DO NOT hold
the button down, only press the
button once. The engine will
attempt to start 6 times.
5. If visible, observe the flashing red light
mounted behind the power panel near
the recoil housing. This light indicates
that the generator is in starting mode.
The light will turn off after the generator
starts.
6. A safety feature is provided which delays
the electrical power availability during
starting mode. The delay lasts for
approximately 15 seconds. The delay is
provided to prevent damage to the
generator if electrical loads are
inadvertently turned on during engine
startup.
7. If the generator fails to start, check the
battery condition and cable connections.
Starting the Engine without
Remote
1.
Make certain the generator is on a flat,
level surface.
2. Turn off all electrical loads connected to
the generator. Never start or stop the
generator with electrical devices plugged
in and turned on.
3. Turn the fuel valve to the "On" position.
4. ELECTRIC START: Press the switch to
the "START" position.
5. RECOIL START: Pull the starter cord
slowly until resistance is felt and then
pull rapidly.
Operation
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents