201174 - POwER DiSTRibUTiON bOx

Parts included

Accessories
L14-30P x 14-50R Adapter
L14-30P x TT-30R Adapter

OPERATiON

The outdoor rated Power Distribution Box is used to bring
electrical power to remote locations away from a primary
power source through the use of a Champion 30-Foot 50-Amp
125/250-Volt power Cord #100828 (not included) or equivalent.
To order Power Cord 100828, please call customer service at
1-877-338-0999 or visit www.championpowerequipment.com
Power source can be a 125/250V, 50A maximum generator or
utility. The power cord plugs into the power source and into the
power inlet receptacle on the Power Distribution Box. The power
inlet feeds a split-phase circuit breaker with (6) 1-pole 20A circuit
breakers and (1) 2-pole 30A circuit breaker.
Each 20A circuit breaker powers and protects a 120V 20A GFCI
5-20R receptacle. The 30A circuit breaker powers and protects a
120/240V 30A L14-30R locking receptacle. The 30A receptacle is
NOT ground fault protected.
1. Using a power cord, connect 125/250V power source to 50A
SS2-50P inlet receptacle.
2. Confirm all circuit breakers are in the ON position.
3. Test and reset each GCFI receptacle. The green power
indicating light shall be illuminated.
4. Power Distribution Box is ready for use.
The upstream circuit breaker from the Power Distribution Box
shall have an interrupting current rating of at least 10,000
amperes.
. .......................................
. .......................................
NOTiCE

GfCi

Your Power Distribution Box is equipped with ground fault circuit
interrupter (GFCI) receptacles. In the event of a ground fault, a
1
GFCI trips automatically to stop the flow of electricity and prevent
1
serious injury. The green indicator light (A) on the receptacle will
also turn off. Press the "RESET" (B) button located on the front of
the receptacle to restore flow of electricity. The indicator light will
also turn back on. GFCI does not protect against circuit overloads.
To ensure proper operation of the GFCI duplex, perform this test
monthly:
1. With the Power Distribution Box running, plug a lamp into the
GFCI receptacle. Turn the lamp on.
2. Press the "TEST" (C) button located on the front of the
receptacle to trip the device. This should immediately stop
the flow of electricity and shut off the lamp. If the electricity
is not stopped, do not use this receptacle until it has been
serviced or replaced.
3. Press the "RESET" button located on the front of the
receptacle to restore the flow of electricity. If the indicator
light does not come back on or if the GFCI cannot be reset
then it must be replaced.
A
b
In any electrical application, some current will flow through
the protective ground conductor to the ground, this is called
leakage current. It takes 4 mA (0.004 A) and higher of leakage
current from the hot wire to the ground to cause a GFCI to trip.
On circuits protected by GFCI's, leakage current can cause
unnecessary and intermittent tripping.
Some stationary motors, such as a bathroom vent fan,
fluorescent lighting fixtures or some refrigerators, may produce
enough leakage to cause nuisance tripping. To avoid nuisance
tripping, a GFCI should not supply:
– Fluorescent or other types of electric-discharge lighting
fixtures.
– Permanently installed electric motors, like air conditioners,
furnaces or refrigerators.
7