7. On the right rear sidewall there is a double column of
screws. Remove the center screw. Locate the safety
chain and a #10 x 1/2" sheet metal screw from the
parts bag. Insert the screw through the closed end
link of the chain and tighten in the vacant screw
hole. The chain can now be used to secure the tank,
preventing damage to the regulator.
8. CO2 tanks are shipped empty and must be filled prior
to use. Turn the adjusting screw on the regulator
counter-clockwise one turn. Make sure that the valve
at the bottom of the regulator where the red hose is
connected is in the off position as shown. Open the
tank valve. Watching the secondary pressure gauge,
turn the regulator adjusting screw clockwise until the
pressure is at 15 psig or required rack-off pressure.
Adjustments can later be made based on flow rates.
9. Locate the beer faucet(s) and install onto the
dispensing head shanks. Tighten with supplied
spanner wrench. Install black handle(s) onto faucet(s).