Hitachi KP-F145WCL Operation Manual page 14

High pixel ccd camera
Table of Contents

Advertisement

Ex.1 Exposure time = setting value XYY
X
int
2
  
YY
int
int
  
C7
  
XYY
Ex.2 Setting value 25D
ShutterSpe
ed
(4) DATA BIT : Setting of output bit depth
8bit (Factory setting)
10bit
12bit
(5) VD/FVAL : Setting of vertical sync signal
VD
FVAL (Factory setting)
(6) HD/LVAL : Setting of horizontal sync signal
HD
LVAL (Factory setting)
(7) GAIN : Setting of electrical sensitivity
0 (Factory setting) to 18dB : Set from 0 to 18dB in 504 steps.
(8) BLACK LEVEL : Adjust offset level
0 (Factory setting) to 63 : Set in 64 steps.
(9) VERTICAL 2 PIXEL ADDITION : Setting of vertical two pixel addition
OFF (Factory setting)
ON
(10) PARTIAL SCAN : Setting about partial scan
-MODE- : Select of mode
OFF (Factory setting)
ON
-START- : Start position of partial scan
1 (Factory setting) to 1040: Scan is started from the line set up in 1 to 1040.
-WIDTH- : Width of partial scan
1 to 1040 (Factory setting): Scan is performed number of line set up in 1 to 1040 is scanned.
* When using partial scan, please make sum total of START and WIDH into 1041 or less.
* When using partial scan, please use FVAL.
16
log
8000
1
8000
100
16
1
2
1
10
9
100
16
7
9
16
2C7
16
that produces 1/234.22 second exposure time.
16
5D
2 1
10
1
16
9
(
)
100
16
4269.53
  
[
sec]
1
[sec]
  
234.22
: Image is outputted by 8 bit.
: Image is outputted by 10 bit.
: Image is outputted by 12 bit.
: Output VD.
: Output FVAL.
: Output HD.
: Output LVAL.
: Not perform vertical two pixel addition.
: Perform vertical two pixels addition and frame rate is increased about 2 times.
: Not perform partial scan.
: Perform partial scan.
to obtain 1/125 second (= 8000μsecond).
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kp-f500wclKp-fr500wcl

Table of Contents