Setting Data Error And Data Buffer Options - NCR 7193 Service Manual

Thermal receipt printer
Hide thumbs Also See for 7193:
Table of Contents

Advertisement

7193 Service Guide

Setting Data Error and Data Buffer options

This function allows you to select the handling of data reception errors (RS-232C only) and
to select the size of the data buffer (RS-232C and Parallel only).
Caution: The DIP switches are pre-set at the factory and should generally not be changed.
If you must change them, do so carefully to avoid changing other functions. Run the print
test to see the current settings for this function. See "Testing The Printer" in chapter 2.
1.
2.
3.
Switch 1
On
On
On
On
1 Default
2 RS-232C only
3 RS-232C and Parallel only
Choose one of the Data Errors options and one of the Data Buffer options.
4.
5.
6.
Turn the power off.
Turn the printer over and note what the current DIP switch settings are.
Set the switches to the settings in the table you want for data reception errors and the
data buffer.
Switch 2
Switch 3
Off
On
Off
On
Off
On
Off
On
Turn the power back on to enter the settings into the EEROM.
On remote models, the On Line light (green) blinks.
Turn the power off.
Set the DIP switches to the former settings.
DIP switch 1 must be Off to return the printer to the RS-232C .
Switch 4
Switch 5
Switch 6
Off
Off
Off
Off
Off
On
Off
On
Off
Off
On
On
August 1998
Chapter 3: Diagnostics
Option
"?" for Data Errors 1, 2
Ignore Data Errors 2
4K Byte Data Buffer 1, 3
One Line Data Buffer 3
23

Advertisement

Table of Contents
loading

Table of Contents