Adjustment Procedures; Preparation - Icom IC-F4001 Service Manual

Table of Contents

Advertisement

SECTION 5.

5-1 PREPARATION

¤ REQUIRED EQUIPMENTS
EQUIPMENT
CS-F3000 CLONING SOFTWARE
Cloning software
(Revision 1.0 or later)
Measuring range
RF power meter
Frequency range
(50 Ω terminated)
SWR
Modulation
Frequency range
Analyzer
Measuring range
AC millivoltmeter
Measuring range
Frequency range
Oscilloscope
Measuring range
Audio generator
Frequency range
(AG)
Output level
¤ JIG CABLE
[JIG cable1]
3-conductor 2.5 (d) mm plug
(MIC)
[JIG cable2]
3-conductor 3.5(d) mm plug
ADJUSTMENT PROCEDURE
GRADE AND RANGE
: 0.1–6 W
: 100–600 MHz
: Less than 1.2 : 1
: 30–600 MHz
: 0 to ±10 kHz
: 10 mV to 10 V
: DC–20 MHz
: 0.01–20 V
: 300–3000 Hz
: 1–500 mV
AUDIO GENERATOR
(300–3000 Hz/1–500 mV)
(GND)
PTT
33 k
+
4.7 µF
(SP)
(GND)
(CLONE)
EQUIPMENT
Modifi ed OPC-478/U/UC
JIG cable
(See the illusted below)
Frequency range
Frequency counter
Frequency accuracy : ±1 ppm or better
Input level
Frequency range
Standard signal
Output level
generator (SSG)
Power attenuation
Attenuator
Capacity
Input impedance
External speaker
Capacity
SETTING;
Frequency : 1 kHz
Level
+ −
Waveform : Sine wave
+
EXT. SPEAKER
(1 W/8 Ω)
OPC-478/U/UC
5 - 1
GRADE AND RANGE
: 0.1–600 MHz
: Less than 1 mW
: 0.1–600 MHz
: –20 to 90 dBµ
(–127 to –17 dBm)
: 30 dB
: More than 6 W
: 8 Ω
: More than 1 W
AC
MILLIVOLTMETER
(10 mV to 10 V)
: 1−500mV
+ −

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IC-F4001 and is the answer not in the manual?

Questions and answers

kabindra
February 3, 2025

ptt pressed but not tx

1 comments:
Mr. Anderson
February 10, 2025

The Icom IC-F4001 may not be transmitting when the PTT is pressed due to several possible reasons:

1. Transmit Inhibit Function – Transmission is restricted if:
- The channel is muted (PMR operation only).
- The channel is busy.
- A signal with an unmatched (or matched) CTCSS or DTCS tone is received.
- The selected channel is a "receive only" channel.

2. Time-Out Timer – If the transceiver has been transmitting continuously beyond the pre-programmed time limit, the time-out timer activates and stops further transmission.

3. Penalty Timer – After the time-out timer activates, the penalty timer may further inhibit transmission for a set period.

4. Power Supply Issues – If the transceiver is connected to a power supply with incorrect voltage or reversed polarity, it may not function properly.

5. Antenna Damage – If an RF signal stronger than 20 dBm (100 mW) was applied to the antenna connector, the transceiver’s front-end could be damaged, affecting transmission.

Checking these factors can help identify and resolve the issue.

This answer is automatically generated

kabindra
February 16, 2025

Q73 trasistor does not work when PTT pressed but software is ok

This manual is also suitable for:

Ic-f4002Ic-f4003Ic-f4006Ic-f4008

Table of Contents

Save PDF