Isolating Relay; Xy-Capacitor; Micro Switches - Fisher & Paykel OB30DDEPX1 Service Manual

Hide thumbs Also See for OB30DDEPX1:
Table of Contents

Advertisement

Service Manual 547226: OB30
MTL (Microtemp Limiter)
This is a non-resettable thermal limiter positioned to detect
electronics area over temperature caused by a cooling fan
failure. It will cut power to the power transformers,
disabling the oven when tripped.
Capacity Rating:
Trip Temperatures:
TL 1 & TL 2
These are non-resettable thermal limiters positioned to
detect the upper cooling fan failure on a double oven. They
will cut power to the oven elements when tripped.
Capacity Rating:
Trip Temperatures:

2.27 Isolating Relay

(Double Line Break Relay)
This relay switches the elements, cavity fan and vent
fan on the opposite side to the power module relay
switches.
It is only energised when an oven mode is selected.
Coil Voltage:
Coil Input:

2.28 XY-Capacitor

This capacitor provides surge protection for the oven.
Voltage:
Class:
Temp Range:

2.29 Micro Switches

There are three micro switches in the door lock assembly.
Voltage
25 Amps at 240
VAC.
200°F (93°C)
16 Amps at 12VDC
284°F (140°C)
12
VDC
1 watt
250 VAC
X2Y2
- 105 to 210°F (-40 to 100°C) (Refer fig.8a)
12
VDC
(Refer fig.5.25)
18
December 2012
Figure 2.28c
Figure 2.28d
Figure 2.29