Wiring Diagram; Install The Optional Soffit Chimney; Install Blower; Install Light Bulbs And Warming Lamps - Rangemaster RM60000 SERIES Installation Instructions And User Manual

Range hood
Table of Contents

Advertisement

Available languages

Available languages

10. WIRING DIAGRAM

11. INSTALL THE OPTIONAL SOFFIT CHIMNEY

(OPTIONAL) RMN Series
Refer to the instructions included with the soffit chimney.

12. INSTALL BLOWER

Refer to instructions included with blower.
Once the blower is installed, plug the blower unit into the female receptacle
and the power supply onto the male connector inside the hood. DO
NOT plug the two cords into each other.

13. INSTALL LIGHT BULBS AND WARMING LAMPS

Install (2) heat lamp bulbs. Use BR40 size, 250W Max., infrared bulbs only (purchase separately).
Install (3) halogen light bulbs. Use PAR20 50W Size (purchase separately).
B
120V 60H
Z IN
TO FAN MOTOR
B
W
B
G
HS
B
SPEED
THERMOSTAT
NEMA
CONTROL
5-15
P PLUG
TERMINAL BLOCK
W
W
RIGHT HEAT LAMP SWITCH
W
FAN SWITCH
B
B
LIGHTS SWITCH
B
B
LEFT
HEAT LAMP SWITCH
W
W
W
W
W
- 8 -
RIGHT HEAT LAMP SOCKET
B
W
RIGHT LIGHT
SOCKET
W
B
W
CENTER LIGHT SOCKET
B
W
LEFT LIGHT SOCKET
B
W
LEFT HEAT LAMP SOCKET
B
W
HE0003