Clearances From Combustibles - Osburn 1600 Owner's Manual

Us environmental protection agency phase ii certified woodstoves
Table of Contents

Advertisement

CLEARANCES FROM COMBUSTIBLES

It is of outmost importance that the clearances to combustible materials be scrupulously
respected upon installation of the stove you have selected. Refer to the tables below :
To Unit:
Sidewall
A
Backwall
B
Corner
C
To Connector:
Sidewall
D
Backwall
E
Corner
F
From Hearth:
Ceiling Height
Floor to ceiling height must be at least 7' (84") in all cases.
The clearance between the flue pipe and a wall are valid only for vertical walls and for
vertical flue pipe.
The flue pipe must not go through roof trussing, an attic, a wardrobe, a floor, a
combustible partition, or similar spaces.
A flue pipe crossing a combustible wall must have a minimum clearance of 18".
To reduce flue pipe clearances from combustible materials, contact your local safety
department.
VERTICAL
& HORIZONTAL
SINGLE
WALL
CONNECTOR
16.5" (419 mm)
15"
(318 mm)
11.5" (292 mm)
26"
(660 mm)
21"
(533 mm)
23.5" (597 mm)
84"
(2135 mm)
SECURITY
DOUBLE
WALL
20.5" (521 mm)
6"
(152 mm)
5.5"
(140 mm) CAN.
29"
(737 mm)
25"
(635 mm) CAN.
10"
(254 mm)
16"
(406 mm)
84"
(2135 mm)
INDUSTRIAL
CHIMNEY
COMPANY
DOUBLE
WALL
16.5" (420 mm)
6"
(15 mm)
6"
(150 mm)
25"
(635 mm)
10"
(254 mm)
12"
(305 mm)
84"
(2135 mm)
10