SWITCH THERMOSTAT(BIMETAL)
function : control the duct temperature, if the temp reached over 150°C, all power supply will be cut. and if the temp go down
120°C the power will be ON.
protecting overheating by cutting off heater power supply if the temperature rises over 150°C, and reoperating heater
by connecting heater power supply if the temperature falls under 120°C.
• OPERATING TEMPERATURE
OPEN TEMPERATURE(OFF)
CLOSE TEMPERATURE(ON)
UNIT FAN MOTOR
function : circulating the inside air during dry process.
• SPEC
ITEMS
RATING VOLTAGE
MOTOR
RPM
DUCT FAN AS
ROTAING DIRECTION
• FAILURE MODE : * E3 shown : FAN MOTOR cannot work.
• CHECKING METHOD : Check the FAN MOTOR is short, and replace with new one.
150°C ± 5°C
120°C ± 5°C
SPEC
24V
3700 ± 10%
1900 ± 10%
CW